Texas & Oklahoma utilities and infrastructure since 1984Data center projects nationwide Find your repAbout(281) 363-1106Request a quote
Ryan Sales — Medium & High Voltage Specialists Get a quoteQuote
Lindsey Systems logo

Lindsey Systems Sensors Representative in Texas & Oklahoma

Est. 1947 · Azusa, CA

Ryan Sales represents Lindsey Systems in Texas and Oklahoma. We help utility and co-op engineers apply Lindsey voltage and current sensors for automation and metering, and transmission line monitoring and rating tools for FERC Order 881 work.

Lindsey Systems products

Voltage & Current Sensors

Lindsey Systems 200A Separable Connector Voltage SensorsLindsey Systems200A Separable Connector Voltage Sensors15 kV, 25 kV, 35 kV classIEEE 386 elbow and T-body voltage sensors for 200A deadfront padmount and underground equipment.Lindsey Systems Busbar Style SensorsLindsey SystemsBusbar Style SensorsMedium voltage substation (through 35 kV class)Busbar-mount current and voltage sensors with standard 2- or 4-hole NEMA pads for substation installations.Lindsey Systems CVMB Current & Voltage Sensing BushingLindsey SystemsCVMB Current & Voltage Sensing BushingMedium voltageCombined current and voltage sensing bushing for switchgear and equipment OEMs.Lindsey Systems Clamp-Top Line Post SensorsLindsey SystemsClamp-Top Line Post SensorsMedium voltage distribution (15-35 kV class)Drop-in clamp-top sensors that replace existing horizontal or vertical line post insulators without cutting the conductor.Lindsey Systems ElbowSense Voltage SensorsLindsey SystemsElbowSense Voltage Sensors15 kV, 25 kV, 35 kV classSubmersible-rated 600A/900A elbow voltage sensors for underground switchgear and vault applications.Lindsey Systems GEN2 MultiCore Line Post SensorLindsey SystemsGEN2 MultiCore Line Post SensorMedium voltage distribution (15-35 kV class)Combined current/voltage line post sensor delivering 0.2% voltage accuracy for smart grid monitoring on overhead distribution lines.Lindsey Systems LEA/LPIT Low Energy Analog SensorsLindsey SystemsLEA/LPIT Low Energy Analog SensorsMedium voltageIEEE C37.92 / IEC 61869 compliant low energy analog sensors with RJ-45 connectivity for modern protective relays.Lindsey Systems Neutral Current SensorLindsey SystemsNeutral Current SensorMedium voltage distributionNeutral current sensor for detecting unbalance on overhead and padmount distribution capacitor banks.Lindsey Systems SF6 Voltage Sensors, Through 25 kV classLindsey SystemsSF6 Voltage SensorsThrough 25 kV classVoltage sensors designed for SF6 gas-insulated switchgear through 25 kV.Lindsey Systems SVMI Voltage SensorsLindsey SystemsSVMI Voltage SensorsMedium voltage distribution (15-35 kV class)Compact voltage-only sensors sized for recloser and switch installations, with a higher-accuracy option.Lindsey Systems Standoff Insulator Voltage Sensors (VMI)Lindsey SystemsStandoff Insulator Voltage Sensors (VMI)Medium voltage (through 35 kV class)High-accuracy standoff insulator voltage sensors with flat response through the 20th harmonic.Lindsey Systems Traditional Line Post Insulator SensorsLindsey SystemsTraditional Line Post Insulator SensorsMedium voltage distribution (15-35 kV class)Proven line post insulator sensors providing voltage-only, current-only, or combined sensing with field-demonstrated reliability.Lindsey Systems Tube Type Substation SensorsLindsey SystemsTube Type Substation SensorsMedium voltage substation (through 35 kV class)Threaded-conductor tube style sensors for substation current and voltage measurement.Lindsey Systems Type 9561 LV Switchgear Voltage Sensor, Up to 1000 VACLindsey SystemsType 9561 LV Switchgear Voltage SensorUp to 1000 VACLow voltage switchgear sensor measuring circuits up to 1000 VAC with 0.5% or 1% accuracy.Lindsey Systems Type LVS Live Front Voltage SensorLindsey SystemsType LVS Live Front Voltage SensorMedium voltage (through 35 kV class)Compact voltage sensor for space-limited live-front air-insulated switchgear.Lindsey Systems Type UOV Oil-Filled Voltage Sensor, Through 35 kV classLindsey SystemsType UOV Oil-Filled Voltage SensorThrough 35 kV classUnder-oil voltage sensors for oil-filled transformers and switchgear up to 35 kV.Lindsey Systems Underground Current SensorsLindsey SystemsUnderground Current SensorsMedium voltage underground (through 35 kV); 600 V versionsRing-type and split-core current sensors, including Rogowski coil options, for underground and switchgear circuits.Lindsey Systems Underground Power Supply, 12 VDC outputLindsey SystemsUnderground Power Supply12 VDC outputPatented sensor-powered 12VDC supply with battery backup for powering devices in underground enclosures.Lindsey Systems Wildlife Covers for SensorsLindsey SystemsWildlife Covers for SensorsMedium voltage distributionSnap-on animal protection covers for Lindsey GEN2 and SVMI sensors to reduce wildlife-related outages.

Transmission Line Monitoring & Line Rating

About Lindsey Systems

Lindsey Systems traces back to Lindsey Manufacturing Company, which its founder started in 1947 in a garage in Pasadena, California. The company is now based in Azusa, California, and makes transmission and distribution products for the electric power industry.

It is known for its sensor systems, its SMARTLINE platform for dynamic line ratings, and its Emergency Restoration Systems for transmission lines.

Why buy Lindsey Systems through Ryan Sales

Sensors only pay off when they match the relay, controller or RTU they feed, and a rep helps you get that match right the first time. We work with your protection, automation and transmission planning engineers from selection through commissioning.

  • Application help. We help pick sensor type, accuracy class and output (including low energy analog outputs) for the control or relay on the other end.
  • Factory access. We connect you with Lindsey engineers on integration, SMARTLINE configuration and line rating methods.
  • Quotes and lead times. We get current lead times for sensor retrofits and new-build packages.
  • Regional reps. A rep in your part of Texas or Oklahoma supports you from pilot through system rollout.

Related guides: LPIT sensors vs. CTs and PTs · FERC Order 881 line ratings · Grid equipment for wildfire mitigation

Your Lindsey rep

Central/South Texas: Chad Ryan, Shane Ryan, Brent Tucker · Gulf Coast: Ryan Vinson · North Texas & Oklahoma: Jared Vanlandingham · West Texas: Derek Jones. Find your rep

Frequently asked questions

Who is the Lindsey Systems rep in Texas?

Ryan Sales represents Lindsey Systems in Texas and Oklahoma, covering overhead, underground and substation sensors plus transmission line monitoring. Regional reps serve Central/South Texas, the Gulf Coast, North Texas and Oklahoma, and West Texas. Call (281) 363-1106 or find your rep to reach the right person.

Can Lindsey sensors work with my existing recloser control or relay?

Usually, but it depends on the input the control expects. Lindsey offers conventional sensor outputs and low energy analog (LEA/LPIT) versions, so the right choice follows from your relay or controller model. Send us the make and model and we will confirm compatibility with Lindsey before you order.

How does Lindsey help with FERC Order 881 ambient-adjusted ratings?

Lindsey's SMARTLINE-AAR/881 tool calculates ambient-adjusted ratings, and SMARTLINE-GT and SMARTLINE-TCF add digital twin ratings and capacity forecasting. Line conductor monitors can supply field data. See our FERC Order 881 guide for background on the requirement.

Talk to a Lindsey rep

Tell us what you need to measure and where, and we will match Lindsey sensors or line monitoring to your system. Call (281) 363-1106 or request a quote.

Request a quote Call