Lindsey Systems

Transmission Line Conductor Monitor

The Lindsey Systems TLM is a transmission line conductor monitor for lines through 765 kV, used for dynamic line rating and clearance compliance, sold and supported in Texas and Oklahoma by Ryan Sales.

  • Live-line installable through 765 kV
  • LiDAR clearance-to-ground
  • conductor temperature, current, inclination/sag, vibration
  • self-powered
  • Iridium satellite communications
Overview

The TLM conductor monitor clamps onto energized transmission conductors through 765 kV and directly measures clearance-to-ground via LiDAR along with conductor temperature, inclination/sag, current, and vibration. It is self-powered and corona-free, communicating over the Iridium satellite network so no field RTUs or communications infrastructure are required. TLM data feeds the SMARTLINE platform for dynamic line rating.

Specifications
Maximum voltage765 kV
MeasurementsClearance-to-ground (LiDAR); conductor temperature; current; inclination/sag; vibration
Power sourceSelf-powered
CommunicationsIridium satellite
InstallationLive-line installable
CoronaCorona-free

Ratings from manufacturer data. Confirm your configuration with a rep.

Applications
  • Dynamic line rating
  • Clearance compliance
  • Conductor health
  • Congestion relief
Spec sheets & documents
Frequently asked questions
Who sells the Lindsey Systems Transmission Line Conductor Monitor in Texas?

Ryan Sales, a manufacturers' representative based in Magnolia, Texas, sells the Lindsey Systems Transmission Line Conductor Monitor and supports customers across Texas and Oklahoma through regional reps. Call (281) 363-1106 or request a quote on this page.

What does the Lindsey Systems TLM transmission line conductor monitor measure?

The TLM directly measures clearance-to-ground using LiDAR, along with conductor temperature, inclination/sag, current and vibration. It clamps onto energized transmission conductors through 765 kV, and its data feeds the SMARTLINE platform for dynamic line rating, clearance compliance, conductor health and congestion relief.

Does the TLM conductor monitor need field RTUs or a communications network?

No. The TLM is self-powered and communicates over the Iridium satellite network, so no field RTUs or communications infrastructure are required. It is corona-free and can be installed live-line on transmission conductors through 765 kV.