G&W Electric

Fault Location Isolation and Service Restoration

The G&W Electric LaZer Automation FLISR is a 5–38kV fault location, isolation and service restoration system for utility distribution automation and critical facilities, sold and supported in Texas and Oklahoma by Ryan Sales.

  • Closed loop restoration as fast as 8 cycles
  • open loop and multi-source network configurations
  • decentralized or centralized control
  • single-phase isolation
  • up to 5-year warranty
Overview

G&W's FLISR solutions automatically locate faults, isolate the damaged section and restore service to healthy circuit segments - closed-loop schemes restore in as fast as 8 cycles. Architectures can be decentralized or centralized, communicate over fiber, cellular, radio or mesh, and support single-phase isolation to keep unaffected phases energized. With more than two decades of deployments, systems are pre-engineered or custom designed around new and existing switchgear.

Specifications
Voltage class5–38 kV
Restoration timeAs fast as 8 (closed loop) cycles
ConfigurationClosed loop / open loop / multi-source network
ControlsDecentralized or centralized
CommunicationsFiber / cellular / radio / mesh
Phase isolationSingle-phase isolation
WarrantyUp to 5 years

Ratings from manufacturer data. Confirm your configuration with a rep.

Applications
  • Utility distribution automation
  • Universities and military bases
  • Downtown networks
  • Critical facilities
Spec sheets & documents
Frequently asked questions
Who sells the G&W Electric FLISR Distribution Automation in Texas?

Ryan Sales, a manufacturers' representative based in Magnolia, Texas, sells the G&W Electric FLISR Distribution Automation and has represented G&W Electric in Texas since 1984. Its regional reps support customers across Texas and Oklahoma. Call (281) 363-1106 or request a quote on this page.

How fast can G&W Electric's LaZer FLISR system restore service after a fault?

Closed-loop LaZer FLISR schemes restore service in as fast as 8 cycles. The system automatically locates the fault, isolates the damaged section and restores power to healthy circuit segments. Open loop and multi-source network configurations are also available.

What control and communication architectures does LaZer FLISR support?

LaZer FLISR can be decentralized or centralized and communicates over fiber, cellular, radio or mesh networks. It supports single-phase isolation to keep unaffected phases energized, and systems are pre-engineered or custom designed around new and existing switchgear on 5 to 38 kV systems.