JST Power Equipment

J10N Dry Air Gas-Insulated Switchgear

The JST Power Equipment J10N is a 5 kV SF6-free dry air gas-insulated switchgear for primary and secondary power distribution and data centers, sold and supported in Texas and Oklahoma and on data center projects nationwide by Ryan Sales.

  • 5 kV
  • 600 A
  • 20 kA
  • BIL 75 kV
  • SF6-free dry air insulation
Overview

The J10N is JST's environmentally friendly alternative to conventional GIS: it contains no SF6, using dry natural air as the insulating medium. Rated 5 kV, 600 A, 20 kA with 75 kV BIL, it cuts footprint up to 75% versus air-insulated switchgear while reducing installation and maintenance effort. UL listed and built to ANSI, IEEE, and NEMA standards with IEC/IEEE internal arc classification and full front access.

Specifications
Voltage class5 kV
Continuous current600 A
Short-time withstand20 kA
BIL75 kV
InsulationSF6-free dry air
Footprint reductionUp to 75% vs. air-insulated switchgear
Internal arc classificationIEC & IEEE IAC
CertificationsUL listed
StandardsANSI / IEEE / NEMA

Ratings from manufacturer data. Confirm your configuration with a rep.

Applications
  • Primary and secondary power distribution
  • Data centers
  • Renewables
  • Industrial facilities
Spec sheets & documents
Frequently asked questions
Who sells the JST Power Equipment J10N Dry Air Gas-Insulated Switchgear in Texas?

Ryan Sales, a manufacturers' representative based in Magnolia, Texas, sells the JST Power Equipment J10N Dry Air Gas-Insulated Switchgear and supports customers across Texas and Oklahoma and on data center projects nationwide through regional reps. Call (281) 363-1106 or request a quote on this page.

What insulating medium does the JST J10N gas-insulated switchgear use instead of SF6?

The J10N uses dry natural air as its insulating medium and contains no SF6. It cuts footprint by up to 75% versus air-insulated switchgear while reducing installation and maintenance effort, and it carries IEC and IEEE internal arc classification with full front access.

What are the voltage, current and fault ratings of the JST J10N GIS?

The J10N is rated 5 kV, 600 A and 20 kA with 75 kV BIL. It is UL listed and built to ANSI, IEEE and NEMA standards, and it suits primary and secondary power distribution in data centers, renewables and industrial facilities.