Texas & Oklahoma utilities and infrastructure since 1984Data center projects nationwide Find your repAbout(281) 363-1106Request a quote
Ryan Sales — Medium & High Voltage Specialists Get a quoteQuote
G&W Electric

CLiP-LV Low Voltage Current Limiting Protector

The G&W Electric CLiP-LV is a 750 V low-voltage current limiting protector for switchboard protection and distributed generation interconnection, sold and supported in Texas and Oklahoma by Ryan Sales.

  • 750V class
  • up to 4000A continuous
  • up to 200kA interrupting
  • trip levels to 30kA instantaneous
  • 1/4-1/2 cycle clearing
Overview

The CLiP-LV protects low-voltage systems up to 750V from rising fault currents driven by capacity expansion and distributed generation. A continuous copper busbar carries up to 4000A in normal operation while a parallel current limiting fuse clears faults up to 200kA within a quarter to half cycle. Field-adjustable trip levels, remote enable/disable and outdoor-capable construction make it a flexible retrofit for switchboards and bus systems.

Specifications
Voltage class750 V
Continuous currentUp to 4000 A
Fault interruptingUp to 200 kA
Trip levelUp to 30 (instantaneous), field-adjustable kA
Operating time1/4–1/2 cycle
MaterialContinuous copper busbar with parallel current limiting fuse
ControlsRemote enable/disable
EnclosureOutdoor-capable
StandardsUL 248-1 / IEC 60269

Ratings from manufacturer data. Confirm your configuration with a rep.

Applications
  • Low-voltage switchboard protection
  • Distributed generation interconnection
  • Fault current mitigation
Spec sheets & documents
Frequently asked questions
Who sells the G&W Electric CLiP-LV Low Voltage Current Limiting Protector in Texas?

Ryan Sales, a manufacturers' representative based in Magnolia, Texas, sells the G&W Electric CLiP-LV Low Voltage Current Limiting Protector and has represented G&W Electric in Texas since 1984. Its regional reps support customers across Texas and Oklahoma. Call (281) 363-1106 or request a quote on this page.

How does the CLiP-LV clear faults?

The CLiP-LV carries up to 4000 A in normal operation through a continuous copper busbar, while a parallel current limiting fuse clears faults up to 200 kA within a quarter to half cycle. Faults are electronically sensed, with field-adjustable trip levels up to 30 kA instantaneous and remote enable/disable.

What is the difference between the CLiP-LV and the CLiP?

The CLiP-LV is for low-voltage systems up to 750 V, while the CLiP covers 2.8 to 38 kV. The CLiP-LV carries up to 4000 A continuous and interrupts up to 200 kA, meeting UL 248-1 and IEC 60269; the CLiP carries up to 5000 A continuous and interrupts up to 120 kA.

Also in Current-Limiting Fuses & Protectors

View all →

Often specified with

Request a quote Call